Risk Summary
Successful exploitation of this vulnerability could allow unauthorized users to view commands, replay commands, control the device, or stop the device from running.
CVEs (1)
Remediations
- Hetronic recommends that all Nova-M users update their radio transmitters to firmware version r161
- ES-CAN-HL: Main r1864, Estop_v24
- BMS-HL: Main r1175, Estop_v24
- MLC: Main r1600, Estop_v24
- DC Mobile: Main r515, Estop_v24
- The new firmware patches can be obtained free of charge by signing in to the Hetronic website portal or by bringing the transmitter and receiver to any Hetronic service center.
Affected Vendors
Hetronic
Affected Products (5)
Hetronic
·
BMS-HL
< Main r1175 Estop_v24
Hetronic
·
Nova-M
< r161
Hetronic
·
ES-CAN-HL
< Main r1864 Estop_v24
Hetronic
·
MLC
< Main r1600 Estop_v24
Hetronic
·
DC Mobile
< Main r515 Estop_v24
Affected Sectors
Multiple
Get alerted to advisories like this
OTWarden monitors CISA, BSI, Siemens, Rockwell and more — and emails you within 2 hours when your vendors are affected.
Start free trial Learn more