ICSA-21-189-01
·
Published 2021-07-08
·
View on CISA ICS-CERT ↗
Rockwell Automation MicroLogix 1100
CVSS 8.6
HIGH
Risk Summary
Successful exploitation of this vulnerability could allow an attacker to create a denial-of-service condition.
CVEs (1)
Remediations
- A controller in this fault state can be recovered by downloading a new project or an offline copy of the project to the controller. Rockwell Automation recommends users set the controller switch to RUN mode to prevent remote programming. Users are encouraged to have a backup copy of the project in the case it is necessary to recover from an event. Rockwell Automation also recommends users should consider migrating to the Micro870 controller.
- Utilize proper network infrastructure controls, such as firewalls, to help ensure EtherNet/IP traffic from unauthorized sources are blocked.
- Consult the product documentation for specific features, such as a hardware mode switch setting, to which may be used to block unauthorized changes, etc.
- Block all traffic to EtherNet/IP or other CIP protocol-based devices from outside the Manufacturing Zone by blocking or restricting access to TCP and UDP Port 2222 and Port 44818 using proper network infrastructure controls, such as firewalls, UTM devices, or other security appliances. For more information on TCP/UDP ports used by Rockwell Automation Products, see Knowledge Base Article BF7490
- Use trusted software, software patches, antivirus/antimalware programs and interact only with trusted websites and attachments.
- Minimize network exposure for all control system devices and/or systems and ensure they are not accessible from the Internet. For further information about the risks of unprotected Internet accessible control systems, please see Knowledgebase Article PN715
- Locate control system networks and devices behind firewalls and isolate them from the business network.
- When remote access is required, use secure methods, such as virtual private networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices.
- Rockwell Automation users can refer to the Converged Plantwide Ethernet (CPwE) Design and Implementation Guide for best practices for deploying network segmentation and broader defense in depth strategies. Users can also refer to the Rockwell Automation System Security Design Guidelines on how to use Rockwell Automation products to improve the security of their industrial automation systems.
- For more information see Rockwell Automation's Security advisory (Login required).
Affected Vendors
Rockwell Automation
Affected Products (1)
Rockwell Automation
·
MicroLogix 1100
vers:all/*
Affected Sectors
Chemical, Critical Manufacturing, Food and Agriculture, Water and Wastewater Systems