← Back to home
ICSA-21-336-01  ·  Published 2021-12-02  ·  View on CISA ICS-CERT ↗

Schneider Electric SESU

CVSS 3.8 LOW

Risk Summary

Successful exploitation of this vulnerability could cause unintended connection from an internal network to an external network.

CVEs (1)

Remediations

  • If SESU is installed (assuming SESU is configured as “managed product” inside the SESU application) it will indicate a security update is available. Click to download and install the new SESU version.
  • If SESU is not installed, download SESU (automatic download) and follow the installation instructions.
  • Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.
  • Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.
  • Place all controllers in locked cabinets and never leave them in the “Program” mode.
  • Never connect programming software to any network other than the network intended for that device.
  • Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.
  • Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.
  • Minimize network exposure for all control system devices and systems and ensure they are not accessible from the Internet.
  • When remote access is required, use secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN are only as secure as the connected devices.
  • See Schneider Electric Security Notification SEVD-2021-313-02 for more information.

Affected Vendors

Schneider Electric Software, LLC

Affected Products (1)

Schneider Electric Software, LLC · Schneider Electric Software Update >= 2.3.0 | <= 2.5.1

Affected Sectors

Commercial Facilities, Critical Manufacturing, Energy

Get alerted to advisories like this

OTWarden monitors CISA, BSI, Siemens, Rockwell and more — and emails you within 2 hours when your vendors are affected.

Start free trial Learn more