ICSA-22-013-06  ·  Published 2025-05-06  ·  View on CISA ICS-CERT ↗

Siemens SICAM PQ Analyzer

CVSS 3.4 LOW

CVEs (1)

Remediations

  • Update to V3.18 or later version
  • Make sure these executables do not exist, cannot be created or cannot be executed (e.g. by Group Policy Software Restriction): - C:\Program.* - C:\Program Files.* - C:\Program Files (x86)\Siemens.* - C:\Program Files (x86)\Siemens Energy\SICAM\PQ.* Please note that blocking of e.g. "C:\Program.exe" is not sufficient, as the attacker might be able to plant "C:\Program.com", "C:\Program.msi" or an executable with any other extension there.

Affected Vendors

Siemens

Affected Products (1)

Siemens · SICAM PQ Analyzer <V3.18