← Back to home
ICSA-25-317-16  ·  Published 2025-11-11  ·  View on CISA ICS-CERT ↗

Siemens Altair Grid Engine

CVSS 7.8 HIGH

Remediations

  • For clusters not using the UGERest API/daemon remove the setuid-root bit from the binaries for all architectures: chmod u-s $SGE_ROOT/utilbin/<arch>/authuser.
  • Update to V2026.0.0 or later version
  • For non Windows clusters remove the setuid-root bit from the "sgepasswd" binary for all installed architectures: chmod u-s $SGE_ROOT/bin/<arch>/sgepasswd.

Affected Vendors

Siemens

Affected Products (1)

Siemens · Altair Grid Engine vers:intdot/<2026.0.0

Affected Sectors

Critical Manufacturing, Transportation Systems, Energy, Healthcare and Public Health, Financial Services, Government Services and Facilities